{"product_id":"rtch015ta-rheem-pool-chiller-heat-pump-copy","title":"RTCH015TA Rheem Pool Chiller Heat Pump","description":"\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSingle Phase vs Three Phase\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe \u003c\/span\u003e\u003cb\u003eJ models (JQV and JQH)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e operate on a \u003c\/span\u003e\u003cb\u003e220-240V single phase power supply\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e and require a \u003c\/span\u003e\u003cb\u003e40A circuit\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e. They provide a nominal cooling capacity of \u003c\/span\u003e\u003cb\u003e14.63 kW\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e, draw \u003c\/span\u003e\u003cb\u003e4.10 kW\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e of power and achieve a \u003c\/span\u003e\u003cb\u003eCOP of 3.56\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe \u003c\/span\u003e\u003cb\u003eD modes (DQV and DQH)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e operate on a \u003c\/span\u003e\u003cb\u003e380-415V three phase power supply\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e and require only a \u003c\/span\u003e\u003cb\u003e20A circuit\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e. They deliver a slightly higher \u003c\/span\u003e\u003cb\u003e14.79 kW cooling capacity\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e, consume \u003c\/span\u003e\u003cb\u003e3.90 kW\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e of power and achieve a higher \u003c\/span\u003e\u003cb\u003eCOP of 3.79\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e, making them more energy efficient where three phase power is available. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTop Discharge vs Side Discharge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe \u003c\/span\u003e\u003cb\u003eJQV\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e and \u003c\/span\u003e\u003cb\u003eDQV\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e models feature a \u003c\/span\u003e\u003cb\u003etop discharge fan\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e, exhausting air vertically upwards. They require \u003c\/span\u003e\u003cb\u003e2.5 metres of clearance above\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e the unit and have a cabinet size of \u003c\/span\u003e\u003cb\u003e1007 × 650 × 1087 mm\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe \u003c\/span\u003e\u003cb\u003eJQH\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e and \u003c\/span\u003e\u003cb\u003eDQH\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e models feature a \u003c\/span\u003e\u003cb\u003eside discharge fan\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e, directing air horizontally. They require only \u003c\/span\u003e\u003cb\u003e350 mm overhead clearance\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e but need \u003c\/span\u003e\u003cb\u003e2.5 metres of clearance in front of the fan discharge\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e. These models are slightly lower, measuring \u003c\/span\u003e\u003cb\u003e1007 × 650 × 1061 mm\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb\u003eSummary\u003c\/b\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAll four models use the same \u003c\/span\u003e\u003cb\u003etitanium shell and tube heat exchanger\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003cb\u003eRheem IQ Control\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e, \u003c\/span\u003e\u003cb\u003eR410A refrigerant\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e and produce a quiet \u003c\/span\u003e\u003cb\u003e51 dBA\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e noise level. The choice comes down to two factors:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eSingle phase (J models)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e or \u003c\/span\u003e\u003cb\u003ethree phase (D models)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e electrical supply.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cb\u003eTop discharge (QV)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e or \u003c\/span\u003e\u003cb\u003eside discharge (QH)\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e airflow configuration to suit the installation space.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/3704\/5821\/files\/RTCH015TA-JQV-1_spec_2_3.pdf?v=1783318768\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDownload Specifications \u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/3704\/5821\/files\/RTCH015TA-JQH-1_spec_3.pdf?v=1783318766\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDownload Specifications \u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/3704\/5821\/files\/RTCH015TA-DQV-1_spec_3.pdf?v=1783318766\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDownload Specifications \u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/3704\/5821\/files\/RTCH015TA-DQH-1_spec_3.pdf?v=1783318765\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDownload Specifications \u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Rheem","offers":[{"title":"Default Title","offer_id":51930636321085,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0667\/3704\/5821\/files\/ChatGPTImageJul3_2026_04_27_13PM_032c695c-8100-468c-8196-c1df7bd30620.png?v=1784767313","url":"https:\/\/rawspares.com.au\/products\/rtch015ta-rheem-pool-chiller-heat-pump-copy","provider":"Raw Spares","version":"1.0","type":"link"}